Maximum occupancy is calculated at one person per 150 gross square feet for one- and two-family dwellings and per 200 gross square feet for other units, with fractional results rounded upward. For other units, the Fire Inspector may allow one person per 150 gross square feet when the unit meets NFPA 101 Life Safety Code egress and travel requirements and fully complies with the City vacation-rental chapter. PCB Fire Rescue approves the unit’s occupancy after a passed inspection.
The responsible party must be at least eighteen, locally available, reachable by phone twenty-four hours a day, and able to respond physically within one hour when needed. The responsible party monitors the rental at least weekly for compliance. The responsible party is authorized to receive legal notices for the owner.
Designate only one responsible party at a time, arrange an alternate during an individual’s unavailability, and notify the City of a change using its completed form. More than three untimely or inappropriate responses to calls can result in certificate suspension or revocation.
Post the unit address, responsible party’s name and phone number, approved occupancy, trash pickup days, nearest hospital location and an emergency 911 reminder near the main entrance or on the refrigerator. Include beach safety flags and violation penalties, Leave No Trace requirements, a building evacuation map at least 8.5 by 11 inches, and notice that local noise, parking and occupancy violations may produce tickets or citations.
A non-condominium rental displays a sign visible from the street. A condominium or cooperative uses a visible decal or sticker on an exterior door or window. The exterior identification gives the responsible party’s name, twenty-four-hour phone number, and Vacation Rental Certificate or Local Business Tax Receipt number.
Fire-safety equipment and permitted sleeping arrangements must satisfy the inspection conditions.
Panama City Beach operating standards require the approved capacity, interior guest information and exterior rental identification to remain in place during operation.
Smoke alarms must be hardwired and interconnected by wire or Bluetooth with battery backup, in every sleeping room separated by a door or curtain and in hallways serving common sleeping areas, including sleeper sofas. Hearing-impaired guest detectors use flashing lights of at least 100 candela. Combination carbon-monoxide detectors belong in all sleeping areas and on every level when gas appliances or an attached garage are present. Replace smoke alarms every ten years or sooner under manufacturer requirements.
The exception for units built before October 1, 1983 applies only below three stories and uses UL 217 alarms tested weekly and replaced annually. Keep weekly logs of each detector’s location, test date, inspector name and signature, results, maintenance, corrective action and manufacturer schedule. Missing records or inadequate maintenance can require hardwired alarms.
Install an accessible five-pound 2A:10BC extinguisher on every level, serviced annually by a licensed Florida contractor and marked if behind a door. Homes of two or more stories require hardwired UL 924 emergency lighting above stairwells and on upper stair landings, with at least ninety minutes of battery backup; first-floor lighting is exempt. Keep three feet clear around heat sources, equipment rooms clear of storage, outlets and junctions covered, exterior outlets weatherproof, breakers sealed and GFCI protection near water. Extension cords and multiplug adapters cannot serve as permanent wiring.
Correctable violations receive a Notice of Violation warning with a reasonable correction period, followed by a citation for noncompliance. Ordinance 1632 sets $500 for the first violation and $1,000 for the second and each later violation. A third or later violation within twelve months of the first permits certificate suspension or revocation for up to twelve months. The City’s current STR program instead summarizes the third penalty as $1,000 plus one-year revocation; the ordinance authorizes the suspension option and an up-to-twelve-month term. An uncontested civil penalty qualifies for a 50% reduction when paid directly to the City Clerk. Unsafe rentals remain unfit for occupancy until corrected, and additional legal remedies can apply.
Correct inspection deficiencies and complete the reinspection within 30 calendar days. After three failed access attempts the City notifies the owner; a fourth failure can lead to suspension or revocation. Each rental unit needs a separate certificate, with its number in every advertisement. Advertising cannot misrepresent occupancy, parking or restrictive covenants. In units with three or more occupied floors, post evacuation diagrams by the interior bedroom doors on the third floor and above. Ordinance 1632.